Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k
Multi-splitSEER2 21.8 Heats too

Senville · Model SENA-48HF-Q12121212

Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k

A multi-room split system rated at 48,000 BTU covering up to 3,000 sq ft in total across the rooms it serves. It heats in winter too.

$4,300

List price

No live retailer for this exact model right now.

Last listed at Sylvane for $4,399.99 on Oct 27, 2026. We have not been able to confirm it since.

The closest multi-split you can buy today:

Senville Aura Tri-Zone 36,000 BTU Mini Split Heat Pump (25 ft line set)Senville Aura Tri-Zone 36,000 BTU Mini Split Heat Pump (25 ft line set)36,000 BTU · quiet at 38 dB In stock$3,209.99View

Or look for this exact model on Amazon:

Search Amazon

compare.ac may earn a commission on purchases, at no cost to you. As an Amazon Associate I earn from qualifying purchases.

Sizing this system

This is a whole-home system: its rated cooling is shared across several indoor units or distributed through ductwork, so there is no single room it does or does not fit. An installer sizes each zone against that room (a Manual J calculation), which is why we do not print a room verdict here.

Running cost

Mini-splits are rated on SEER2, a seasonal scale, not the ENERGY STAR annual-kWh figure this dollar estimate is built from, so there is no comparable figure to show here. A blank is missing data, not a worse result: a mini-split is often the more efficient choice.

Installation cost

$5,000-15,000 fully installed depending on the number of zones (roughly $3,000-8,000+ for the multi-zone install on top of the equipment). A 2-room (2x1) setup sits near the lower end, a 4-5 room whole-home system near the top. The unit price you see here is hardware only; installation is the larger, separate cost.

A typical range for this system type, for comparison only, not a quote for this unit. The actual price depends on the line-set run, electrical work and access.

Compare similar units

At a glance

Best for cooling several rooms from one outdoor unit.

Cooling
48,000 BTU
Size
Average
Noise
48 dB
Audible
Install: Certified installerPermission: Usually needs permission

Performance

Cooling capacity
48,000 BTU · 14.1 kW
Heating capacity
48,000 BTU
Heats down to
32°F outdoors
Total coverage
up to 3,000 sq ft
Energy Star
Not published
SEER2
21.8
EER2
11.7
Annual energy (cooling)
Not published

Noise, size & features

Model number
SENA-48HF-Q12121212
Indoor noise
48 dB(A)about as loud as a refrigerator
Outdoor noise
Not published
Indoor unit
48.69 x 13.39 x 10.16 in
Outdoor unit
37.24 x 31.89 x 16.14 in (W x H x D)
Refrigerant
R-454B
Wi-Fi / app
Not published
Outdoor unit needed
Yes
Power supply
208/230 V
Warranty
10-Year Compressor Warranty; 5-Year Parts Warranty

SEER2, EER2, heating capacity, heating limit, supply voltage, refrigerant, outdoor unit size and warranty are from Sylvane's published specifications for this exact configuration, checked Oct 2, 2026.

Power while cooling: From its rated cooling capacity divided by its EER2 rating, which is the draw at its rating point (95°F outside). An hour's cost is at that draw and the US average electricity price of 18.44¢/kWh (U.S. Energy Information Administration, Electric Power Monthly Table 5.6.A (residential average, May 2026)). The compressor cycles once the room is cool, so most hours cost less.

Installation & the rules that apply

This is a multi-split. The same EPA Section 608 certified-technician requirement as a single split, applied across a bigger system. Because it touches multiple rooms and routes line sets through the structure, it more often triggers a full permit set (mechanical, electrical and sometimes building), HOA architectural approval, and written landlord consent. Local noise limits at the property line apply to the outdoor unit just as for a single split, though one shared condenser is usually easier to get approved than several separate ones.

Installation

Certified installer

Refrigerant

R-454B

GeneralRenters: get written landlord consent firstReviewed June 2026Often blocks install
United StatesUS: EPA Section 608 certified technician for refrigerantReviewed June 2026Often blocks install
ArizonaArizona: municipal mechanical permit for AC replacementReviewed June 2026Permit required
CaliforniaCalifornia: Title 24 permit and HERS verificationReviewed June 2026Permit required
FloridaFlorida: hurricane wind-load anchoring of outdoor unitsReviewed June 2026Permit required
See full rules by region

Common questions about the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k

How loud is the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k?
48 dB(A) indoors, about as loud as a refrigerator.
How energy-efficient is the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k?
Its efficiency rating is SEER2 21.8.
How many watts does the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k use?
About 4,103 watts while cooling at full power: its rated 48,000 BTU divided by its EER2 of 11.7, the draw at its rating point (95°F outside). At the US average electricity price that is about $0.76 an hour; once the room is cool the compressor cycles, so most hours cost less.
Do I need a professional to install the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k?
Yes. As a multi-split it needs a certified installer. Usually needs permission.
Does the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k heat as well as cool?
Yes. It is a heat pump that also heats, rated 48,000 BTU of heating output.
How cold can it get outside before the Senville Aura 48,000 BTU Quad Zone Mini Split Heat Pump 12k+12k+12k+12k stops heating?
Its retailer's specification for this exact configuration rates it to keep heating down to 32°F outdoors. That is its operating limit, not its full output: a heat pump delivers less heat as it gets colder, so size it for your coldest days.